Construction site incident CASE – 1 Brief Description: A crew of 3 persons was probably actively involved in shifting the Crawler crane from the site and they were below the mast at the time of movement of the crane. During this process mast of the crane fell suddenly causing injury to them. Immediately all three ..read more
RLS HUMAN CARE
4y ago
What is the lux level In short Lux level is a mesurement of light (illumination) lumens/m² As per (Bureau of Indian standard) BIS:6665 Lightning standard at the workplace: General factory areas: Average LUX Level Limiting Glare Index Canteens 150 – Cloakrooms 100 – Entrances, corridors, stairs 100 – Factory outdoor Average LUX Level Limiting Glare ..read more
RLS HUMAN CARE
4y ago
YASHASHWI RASAYAN PRIVATE LIMITED DAHEJ INCIDENT REPORT DESCRIPTION OF THE INCIDENT As per the information received, the Incident happened due to the mixing of Dimethyl Sulphate and Concentrated Nitric Acid. Nitric acid tanker unloaded in the tank of Dimethyl Sulphate by mistake on 02.06.2020. Management decided to tackle this emergency on the next morning, till ..read more
RLS HUMAN CARE
4y ago
40-45 workers injured in fire triggered by blast in chemical factory boiler at Dahej in Gujarat’s Bharuch According to the collector. Time: 03/06/2020 12:20 PM Company : Yashswi Chemicals Pvt. All villages near the factory being evacuated as a precaution measure, Fire bridge trying to extinguish the ?. As per official said all the injured ..read more
RLS HUMAN CARE
4y ago
Dear safety professionals, COVID19 continues to affect every corner of the globe and we hope every in our RLS HUMAN CARE community is staying safe and putting their health and well-being first. Let me tell you that the coronavirus epidemic has made a deep impact on our way of life and occupation. People working in ..read more
RLS HUMAN CARE
4y ago
Gas leak in vizag As per the official said LG polymers Gas leakage in Vizag Andhrapredesh nearly 5000 people fell sick and 11 people died due to Styrene. As per the reports the gas leakage happened around 3:00 am 7/5/2020 at LG Polymers company, Venkatapuram near Naiduthota area. The gas leak incident led to panic ..read more
RLS HUMAN CARE
4y ago
Fire Load Calculation A very important factor in establishing the basis for the analysis of the fire risk pertaining to any building/Factory is the concept of “FIRE LOAD” which indicates the quantity of heat liberated per unit area when a building/Factory and its contents are completely burnt. Fire Load Calculation The fire load of a ..read more
RLS HUMAN CARE
4y ago
Construction site incident CASE – 1 Brief Description: A crew of 3 persons was probably actively involved in shifting the Crawler crane from the site and they were below the mast at the time of movement of the crane. During this process mast of the crane fell suddenly causing injury to them. Immediately all three ..read more
RLS HUMAN CARE
4y ago
What is the lux level In short Lux level is a mesurement of light (illumination) lumens/m² As per (Bureau of Indian standard) BIS:6665 Lightning standard at the workplace: General factory areas: Average LUX Level Limiting Glare Index Canteens 150 – Cloakrooms 100 – Entrances, corridors, stairs 100 – Factory outdoor Average LUX Level Limiting Glare ..read more
RLS HUMAN CARE
4y ago
YASHASHWI RASAYAN PRIVATE LIMITED DAHEJ INCIDENT REPORT DESCRIPTION OF THE INCIDENT As per the information received, the Incident happened due to the mixing of Dimethyl Sulphate and Concentrated Nitric Acid. Nitric acid tanker unloaded in the tank of Dimethyl Sulphate by mistake on 02.06.2020. Management decided to tackle this emergency on the next morning, till ..read more